Mitsubishi Electric GOT2000 Series User Manual page 330

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

5) [Print Screen] key
Stores the displayed screen to the SD card in the BMP or JPEG format.
For further information about hard copies, refer to the following:
6) [Cancel Print] key
The touch operation of this key is invalid.
■3. Parameter setting operation
The following describes the procedure of changing the setting of the "Auto tuning" item as an example of the parameter
setting operation.
Step 1.
Touch the [Read All] key.
The parameter values within the servo amplifier are displayed on the screen.
Step 2.
The parameter read confirmation window is displayed.
Touch the [OK] key to read the parameter values within the servo amplifier to the GOT.
9 - 30
9.4 Operations of Servo Amplifier Monitor Screens
9.4.8 Hard copy output
POINT
POINT
POINT
Operations of when [default] is executed for the MR-J3-□A parameters
The operation when [default] is executed differs depending on the displayed parameter screen,
as shown in (1) and (2) below.
(1) Basic setting, gain/filter or extension setting parameter screen
The 000BH processing (reference/writing is possible only for basic setting, gain/filter and
extension setting parameter) is performed.
(2) I/O setting parameter screen
The 000CH processing (reference/writing is possible for all parameters) is performed.