Step 2.
When the channel No. is selected, the screen below is displayed.
Set the network number and the station number of the target controller.
Step 3.
After selecting the station number, touch the [Enter] key. The communication setting window closes and the
system configuration of the set monitor destination is displayed.
■1. Communication setting window
(1) Displayed screen
1)
3)
When the CH No. is input
1) CH No. input area
Set the CH No. for the target controller.
The setting range is [1] to [4].
2) Network No. input area
Set the network No. for the target controller.
The following shows the setting range for each connection type.
• Serial communication connection: [0]
• Ethernet connection, CC-Link IE Controller Network connection, CC-Link IE Field Network connection: [1] to
[239]
• CC-Link (ID) connection: [0]
3) Station No. input area
Set the station No. of the target controller.
When the station No. is set to the host station (FF), set the network No. to 0.
The following shows the setting range for each connection type.
• Serial communication connection: [FF] (Host station)
• Ethernet connection: [1] to [64]
• CC-Link IE Controller Network connection, CC-Link IE Field Network connection: [1] to [120]
• CC-Link (ID) connection: [0] (master station), [1] to [64] (local station)
4) CH No. selection key
Select a CH No.
5) Keys
Keys used for operations in the communication setting window
2)
4)
When the network No., station No.,
and CPU No. are input
1)
3)
2)
16.4 Operation Procedures
5)
16
16 - 9