Operations for Display
This section explains how to display the intelligent module monitor screen after the GOT is turned on.
Step 1.
Turn on the power to the GOT.
Step 2.
Display the Intelligent module monitor screen.
The display methods include the following two types.
• Starting from the special function switch (Intelligent module monitor) set in the project
For how to set special function switches, refer to the following.
• Starting from the utility
After the utility is displayed, touch [Monitor] → [Intelligent module monitor] from the Main Menu.
For how to display the utility, refer to the following.
Step 3.
Set the channel number, network number, station number.
Set the channel number, network numberand station number of the PLC CPU connected to the GOT.
After turning on the GOT, the communication setting window is displayed at the first startup of the intelligent
module monitor only.
For displaying the communication setting window at the second or later startup, touch the [ChNETPCNo]
key on the intelligent module monitor screen.
Step 4.
Starts the intelligent module monitor.
The module format and related data are not displayed at the intelligent module monitor startup.
When reading of module data from the PLC CPU is complete, the module format and related data is
displayed.
When using the RCPU, QCPU (Q mode), QSCPU, or LCPU,you can check the PLC CPU status (PC
information monitor screen),and the module error information and others (Unit Detail Info Screen).
When [END] key is selected, the intelligent module monitoring ends and the display moves to the original
screen where the intelligent module monitor function was begun.
Step 5.
Specify the module to be monitored.
Step 6.
Display the intelligent module monitor menu.
8 - 6
8.3 Operations for Display
GT Designer3 (GOT2000) Screen Design Manual
GOT2000 Series User's Manual (Utility)
8.4 Operation of Each Intelligent Module Monitor Screen
8.4 Operation of Each Intelligent Module Monitor Screen
System Configuration NETWK No. [0] PLC STATION [FF]
MAIN
CPU
Ext.1
Ext.2
Display the System Configuration screen.
8.4.1 Composition of the system configuration screen and key functions
8.4.6 Specifying a module to monitor and selecting monitor menu
8.4.6 Specifying a module to monitor and selecting monitor menu
Communication setting window
NET
END
PC No.
OUT64 IN64
AJ71
IN64
AJ71
PT32-S3
SP
PT32-S3
Y 0
Y 40
X,Y 80
Y 40
X,Y 80
X,Y A0
IN16
OUT32
AJ71
A62LS
A616DA
Y120
Y130
X,Y150
X,Y180
X,Y100
A616AD
A616TD
SP
X,Y200
X,Y260
X,Y230