Drive Recorder Arbitrary Alarm Trigger] Window - Mitsubishi Electric GOT2000 Series User Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

23.4.12 [Drive recorder arbitrary alarm trigger] window

Set the drive recorder arbitrary alarm trigger and write the settings to a target servo amplifier.
1) [Alarm number setting]
Specify an alarm number so that the drive recorder function saves data only when the relevant alarms occur on
a target servo amplifier.
The following shows the details of a servo amplifier alarm.
If you set this item to 0, the drive recorder arbitrary alarm trigger is disabled.
2) [Alarm detail number setting]
Specify an alarm detail number so that the drive recorder function saves data only when a specific alarm occurs
on a target servo amplifier.
If you set this item to 0, the alarms targeted for saving data are determined only by the specified alarm number.
3) Alarm name
Displays the name of the specified alarm.
4) [Write] key
Writes the settings to a target servo amplifier.
Upon completion of the writing, the display returns to the [Drive recorder information list] screen.
The following shows examples of drive recorder arbitrary alarm trigger settings.
Example 1) Specifying AL.10.1 as the target alarm
Set the alarm number to 10, and set the alarm detail number to 1.
Example 2) Specifying AL.10 as the target alarm
Set the alarm number to 10, and set the alarm detail number to 0.
23 - 16
23.4 [Drive recorder information list] screen
1)
2)
3)
4)
AL.**.**
Alarm detail number
Alarm number

Advertisement

Table of Contents
loading

Table of Contents