4) Bit device screen
The common bit devices are always monitored and displayed.
• Bit devices for error detection: marked with a red circle
• Bit devices for general status display: marked with a green circle
(2) Key functions
The following shows the functions of the keys that are used for the operations on the present value monitor screen.
1) [Feed PV] key, [Actual PV] key
The key is displayed in the real mode or the advanced synchronous control mode.
Each touch switches between [Feed PV] and [Actual PV].
2) [Mon. Menu] key
Returns to the monitor menu screen.
3) [END] key
Exits the present value monitor and returns to the screen where the Q motion monitor was started.
4) Keys for switching the displayed axis numbers
Switches the displayed axis number.
The keys are displayed for monitoring Q173CPU, Q173HCPU, Q173DCPU, Q170MCPU, Q172DSCPU, or
Q173DSCPU.
5) [Print Screen] key
Stores the displayed screen to the SD card in the BMP or JPEG format.
For further information about hard copies, refer to the following:
6) [Cancel Print]
The operation of this key is invalid.
7 - 14
7.4 Operation Procedures
1)
5)
6)
7.4.12 Hard copy output
2)
3)
4)
4)