4.3

Display Operation

This section explains how to display the operation screen for the sequence program monitor (Ladder) or the sequence
program monitor (R ladder) after the GOT is turned on.
Step 1.
Power on the GOT.
Step 2.
Display the sequence program monitor (Ladder) screen or the sequence program monitor (R ladder)
screen.
The display methods include the following two types.
• Using the special function switch (Sequence program monitor (Ladder) or Sequence program monitor (R
ladder)) set in the project
For how to set the special function switch, refer to the following.
• Starting from the utility
To start the sequence program monitor (Ladder), touch [Monitor] → [Seq.program monitor(Ladder)] from
the main menu.
Touch [Monitor] → [Seq. program monitor] from the Main Menu.
To start the sequence program monitor (R ladder), touch [Monitor] → [Seq. program monitor (R Ladder)]
from the main menu.
For how to display the utility, refer to the following.
Step 3.
Set the channel No., network No., station number, and CPU number in the communication setting dialog.
Step 4.
Read data from the PLC and display the program list window.
Reading data from the PLC is not required when the GOT is restarted, because sequence programs and
comment files are stored in a data storage with the sequence program monitor (Ladder).
Reading data from the PLC is not required when the GOT is restarted, because sequence programs are
stored in a data storage with the sequence program monitor (R ladder).
Step 5.
Select a program to be displayed from the program list and display the ladder monitor screen.
Step 6.
Display the ladder editor screen from the edit menu of the ladder monitor screen.
For information on how to start the sequence program monitor (Ladder) or the sequence program monitor (R ladder) using
the one-touch ladder jump function, refer to the following.
For the changing screens for the security setting, refer to the following.
4 - 10
4.3 Display Operation
GT Designer3 (GOT2000) Screen Design Manual
GOT2000 Series User's Manual (Utility)
4.5.2 ■1. Communication setting window
4.5.2 ■2. Program list window
4.6 How to Operate Ladder Monitor Screen
4.7 How to Operate Ladder Editor Screen
■1. Start operation when using the One-touch Ladder Jump function
4.3.4 Setting the security

Advertisement

Table of Contents
loading

Table of Contents