4.5.2

Key functions

The following shows the functions of the keys used for operating the PLC read screen.
Key
[←Back]
[Select CPU]
[X]
[Recommend]
[Proceed]
4 - 24
4.5 How to Operate PLC Read Screen
Returns the screen to the last screen that is displayed right before the PLC read screen appears.
The key is disabled when the last screen is the GOT utility screen or user-created monitor screen.
Displays the communication setting window.
■1. Communication setting window
Exits the sequence program monitor (ladder) and returns the screen to the sequence program monitor
(ladder) startup screen.
Scrolls the display area up and down by one line.
Scrolls the display area up and down by one page.
This key can be used when program files are displayed in the target drive list (connection destination). (This
key cannot be used in the sequence program monitor (R ladder).)
Touching the key selects all the sequence program files, common comment files, and comment files for the
selected sequence program files in the file list (target controller).
When files with the same name are displayed in the file list (target controller) and file list (GOT), touching the
key selects a file as shown below.
• For sequence program files
When the updated dates and times differ between the files, touching the key selects the file in the file list
(target controller).
When the updated dates and times are the same between the files, touching the key selects the file in the
file list (GOT).
• For comment files
When the updated dates and times differ between the files, touching the key selects the latest file.
When the updated dates and times are the same between the files, touching the key selects the file in the
file list (GOT).
Writes the file selected in the file list (target controller) into the data storage displayed in the target drive list
(GOT).
When the connection destination is an RCPU, data is read from the data storage.
The file written into the data storage on the PLC read screen is stored in the SEQDAT folder.
After writing, among files other than comment files in the data storage, files that are not selected in the file
list (GOT) are deleted. Then, the program list window appears.