6) [Acc/dec time] key
Changes the acceleration/deceleration time constant.
7) [Momentary Switch Operation: Selecting Momentary] key, [Momentary Switch Operation: Not
Selecting Momentary] key
Touching this changes the operation mode (momentary operation/no momentary operation).
• [Momentary Switch Operation: Selecting Momentary]
The servo motor rotates while the [Forward] key or [Reverse] key is touched.
Releasing your finger from these keys stops the operation.
• [Momentary Switch Operation: Not Selecting Momentary]
The servo motor rotates while the [Forward] key or [Reverse] key is touched, stops when the [Pause] key is
touched.
8) [Positioning] key
Changes to the positioning operation screen.
9) [Without Motor] key
Changes to the motor-less operation screen.
10) [DO ForcedOutput] key
Changes to the DO forced output screen.
11) [Print Screen] key
Stores the displayed screen to the SD card in the BMP or JPEG format.
For further information about hard copies, refer to the following:
12) [Cancel Print] key
The touch operation of this key is invalid.
■5. Positioning operation screen
The following describes the display data of the positioning operation screen and the key functions displayed on the
screen.
(1) Displayed contents
1) [Motor speed]
Displays the set speed of the servo motor.
2) [Acc/dec time]
Displays the set acceleration/deceleration time constant.
3) Move distance
Displays the set distance.
9 - 36
9.4 Operations of Servo Amplifier Monitor Screens
■5. Positioning operation screen
■6. Motor-less operation screen
■7. DO forced output screen
9.4.8 Hard copy output
1)
2)
3)