Cnc Data I/O - Mitsubishi Electric GOT2000 Series User Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

Error message
Can not write file
Range Over
Can not write file
In sampling
Can not write file
Can't set superposition waveform
Can not read out file
Filename illegal
Memory Card not exist
The Ethernet settings of the monitoring
target CNC are not correct.
Error
18 - 20
18.5 Error Messages and Corrective Actions
Description
The file cannot be written because of invalid parameter
values.
The file cannot be written to the CNC because sampling
is in execution.
The superposition waveform cannot be set because the
parameters of the wave type 1 and the wave type 2 are
not matched when the wave type 2 is input. For
example, [Superposition] is set to [OFF] in the
parameters of the cycle monitor.
The copy source file cannot be read.
The file name is invalid.
No data storage is inserted into the GOT.
The CNC cannot be connected because the combination
of N/W No. and station No., which are specified in the
project data created with GT Designer3, does not exist in
the Ethernet settings.
Other errors
Corrective action
Check the parameter values.
Write the file to the CNC after sampling is completed.
Correct the parameter settings and input data.
Check if the copy source device is ready for data
reading.
Check the file name, and execute the CNC data I/O
again.
Check that the data storage is inserted into the GOT.
Correct the settings of the special function switch and
Ethernet.
Turn off the GOT and CNC. Check data in the data
storage and the connection status. Then, execute the
CNC data I/O again.