4) PWR ON, PWR OFF
Displays the four past present values of the ABS axis at servo amplifier power-on/off.
At power-on
• Power-on time
• Encoder present value
Multi-revolution data of initial encoder
Single-revolution data of initial encoder
• Servo command value after recovery
• Monitor present value after recovery
• Alarm occurrence information at present value recovery (error code of minor, major error)
At power-off
• Servo amplifier power-off time
• Encoder present value
Multi-revolution data of encoder present value before servo amplifier power-off
Single-revolution data of encoder present value before servo amplifier power-off
• Servo command at servo amplifier power-off
• Monitor present value at servo amplifier power-off
(2) Key functions
1)
1) [1Ax] key
Changes the axes to be monitored.
2) [Mon. Menu] key
Returns to the monitor menu screen.
3) [END] key
Exits the Present Value History Monitor screen and returns to the screen where the Q motion monitor was
started.
4) [Print Screen] key
Stores the displayed screen to the SD card in the BMP or JPEG format.
For further information about hard copies, refer to the following:
7.4.12 Hard copy output
5) [Cancel Print]
The touch operation of this key is invalid.