Sub
05/08
Mode
Element
element
08
Setting
Process
Fuser
Temperature control
mode
lower limit (Plain
paper/Low
temperature)
08
Setting
Process
Fuser
Temperature control
mode
lower limit (Plain
paper/Low
temperature)
08
Setting
Process
Fuser
Temperature control
mode
lower limit (OHP film)
08
Setting
Process
Fuser
Temperature control
mode
lower limit (OHP film)
08
Setting
Process
Fuser
Temperature control
mode
lower limit (Thick
paper 1)
e-STUDIO207L/257/307/357/457/507
Item
Subitem
Code
2206
2206
2207
2207
2208
Sub-
Default
Acceptable
Details
code
value
value
0
Center thermistor
Refer to
0~12
contents
1
Side thermistor
Refer to
0~12
contents
0
Center thermistor
Refer to
0~12
contents
1
Side thermistor
Refer to
0~12
contents
0
Normal
Refer to
0~12
temperature/Center
contents
11
RAM
Contents
M
0: 130°C 1: 135°C 2: 140°C 3: 145°C 4: 150°C 5: 155°
C 6: 160°C 7: 165°C 8: 170°C 9: 175°C 10: 180°C 11:
125°C 12: 120°C
<Default value>
e-STUDIO207L/257/307: 3
e-STUDIO357/457/507: 5
M
0: 130°C 1: 135°C 2: 140°C 3: 145°C 4: 150°C 5: 155°
C 6: 160°C 7: 165°C 8: 170°C 9: 175°C 10: 180°C 11:
125°C 12: 120°C
<Default value>
e-STUDIO207L/257/307: 3
e-STUDIO357/457/507: 4
M
0: 130°C 1: 135°C 2: 140°C 3: 145°C 4: 150°C 5: 155°
C 6: 160°C 7: 165°C 8: 170°C 9: 175°C 10: 180°C 11:
125°C 12: 120°C
<Default value>
e-STUDIO207L/257/307: 3
e-STUDIO357/457/507: 5
M
0: 130°C 1: 135°C 2: 140°C 3: 145°C 4: 150°C 5: 155°
C 6: 160°C 7: 165°C 8: 170°C 9: 175°C 10: 180°C 11:
125°C 12: 120°C
<Default value>
e-STUDIO207L/257/307: 3
e-STUDIO357/457/507: 5
M
0: 130°C 1: 135°C 2: 140°C 3: 145°C 4: 150°C 5: 155°
C 6: 160°C 7: 165°C 8: 170°C 9: 175°C 10: 180°C 11:
125°C 12: 120°C
<Default value>
e-STUDIO207L/257/307: 3
e-STUDIO357/457/507: 6
Proc
Service
edure
UI
4
4
4
4
4