Bpdu-Drop Any; Check Region-Configuration - Huawei Quidway S3900 series Command Manual

Hide thumbs Also See for Quidway S3900 series:
Table of Contents

Advertisement

Command Manual – MSTP
Quidway S3900 Series Ethernet Switches-Release 1510

1.1.2 bpdu-drop any

Syntax
bpdu-drop any
undo bpdu-drop any
View
Ethernet port view
Parameter
None
Description
Use the bpdu-drop any command to configure the BPDU packets drop function on an
Ethernet port.
Use the undo bpdu-drop any command to disable the BPDU packets drop function on
an Ethernet port.
By default, the BPDU packets drop function is disabled on a port.
In an STP-enabled network, someone may ceaselessly send BPDU packets to a switch
for malicious purpose. The switch forwards BPDU packets to other switches by
receiving them, making the STP calculation occurs constantly. Those result in high
CPU consumption, error protocol state of BPDU packets, and so on.
To avoid those problems, you can enable the BPDU packets drop function on the
Ethernet port of the switch. With this function enabled, the port will neither receive nor
forward the BPDU packets, so as to avoid the BPDU packets attack and ensure correct
STP calculation.
Example
# Enable the BPDU packets drop function on Ethernet1/0/1.
<Quidway>system-view
System View: return to User View with Ctrl+Z.
[Quidway] interface Ethernet 1/0/1
[Quidway-Ethernet1/0/1] bpdu-drop any

1.1.3 check region-configuration

Syntax
check region-configuration
View
MST region view
Huawei Technologies Proprietary
1-2
Chapter 1 MSTP Configuration Commands

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents