Command Manual – Auto Detect
Quidway S3900 Series Ethernet Switches-Release 1510
Description
Use the display detect-group command to display the configuration of a specified
detecting group or all detecting groups.
Example
# Display the configuration of detecting group 1.
<Quidway> display detect-group 1
detect-group 1 :
detect loop time(s) : 15
ping wait time(s) : 2
detect retry times : 2
detect ip option : and
register module num : 0
detect ip count : 1
detect-list
1
Table 1-1 Description on the fields of the display detect-group command
detect-group 1
detect loop time(s): 15
ping wait time(s):
detect retry times: 2
detect ip option:
group state:
detecting
register module num: 0
detect ip number:
detect-list
ip address
next hop
group state : not detecting
ip address
202.13.1.55
Field
Detecting group number 1
Detecting interval is 15 seconds.
2
Timeout time of a ping operation is two seconds.
Number of retries of an auto detect operation is 2.
A detecting group is reachable only when all the IP
and
addresses contained in it are reachable.
not
Current state of a detecting group is "not detecting".
Number of registered modules (that is, the number of the
modules utilizing the detecting group.)
1
Number of the IP addresses contained in a detecting group
Sequence number of an IP address contained in a
detecting group
IP address to be detected
Next hop IP address
Huawei Technologies Proprietary
Chapter 1 Auto Detect Configuration Commands
next hop
1.2.3.4
Description
1-3