After the command is executed, you are prompted to enter a password of 1 to 16
characters and make a confirmation. Then the current user interface is locked.
Enter the right password and press <Enter>, and then the user interface is unlocked. If
you have set a password longer than 16 characters, the system only matches the first
16 characters during unlocking. That is, once the first 16 characters are correct, the
user interface will be unlocked.
Example
# Lock the current user interface.
<Quidway> lock
Password:
Again:

1.1.14 parity

Syntax
parity { even | none | odd | }
undo parity
View
User interface view
Parameter
even: Performs even checks.
none: Does not check.
odd: Performs odd checks.
Description
Use the parity command to set the check mode of the user interface.
Use the undo parity command to revert to the default check mode.
Use these two commands in AUX user interface view only.
No check is performed by default.
Example
# Set to perform even checks.
<Quidway> system-view
System View: return to User View with Ctrl+Z.
[Quidway] user-interface aux 0
[Quidway-ui-aux0] parity even