Display Poe Temperature-Protection - Huawei Quidway S3900 series Command Manual

Hide thumbs Also See for Quidway S3900 series:
Table of Contents

Advertisement

Command Manual – PoE & PoE Profile
Quidway S3900 Series Ethernet Switches-Release 1510
<Quidway> display poe powersupply
PSE ID
PSE Legacy Detection
PSE Total Power Consumption :12000 mW
PSE Available Power
PSE Peak Value
PSE Average Value
PSE Software Version
PSE Hardware Version
PSE CPLD Version
PSE Power-Management mode
Table 1-3 Description on the fields of the display poe powersupply command
PSE ID
PSE Legacy Detection
PSE
Consumption
PSE Available Power
Power Peak Value
Power Average Value
Power Software Version
Power Hardware Version
PSE CPLD Version
PSE
mode

1.1.4 display poe temperature-protection

Syntax
display poe temperature-protection
Field
Total
Power
Power-Management
Huawei Technologies Proprietary
Chapter 1 PoE Configuration Commands
:1
:disable
:288000 mW
:12000 mW
:12000 mW
:290
:000
:021
:auto
Description
Identification of the PSE
The enabled/disabled status of the nonstandard PD
detection
Total power consumption of the PSE
Available power of the PSE
Peak power value of the PSE
Average power value of the PSE
Version of the PSE software
Version of the PSE hardware
Version of the PSE complex programmable logical
device (CPLD)
PoE management mode on the port when the PSE is
overloaded:
The auto keyword indicates that the auto mode is
adopted, that is, the PoE management mode based
on the PoE priority of the port is adopted
The manual keyword indicates that the manual
mode is adopted in the PoE management on the port
1-6

Hide quick links:

Advertisement

Chapters

Table of Contents
loading