Huawei Quidway S3900 series Command Manual page 901

Hide thumbs Also See for Quidway S3900 series:
Table of Contents

Advertisement

Command Manual – SNMP and RMON
Quidway S3900 Series Ethernet Switches-Release 1510
View
Any view
Parameter
prialarm-entry-number: Extended alarm entry Index, in the range of 1 to 65535. If you
do not specify this argument, the configuration of all the extended alarm entries is
displayed.
Description
Use the display rmon prialarm command to display the configuration of a specified
RMON extended alarm entry or all the RMON extended alarm entries.
Related command: rmon prialarm.
Example
# Display the configuration of all the extended RMON alarm entries.
<Quidway> display rmon prialarm
Prialarm table 1 owned by user1 is VALID.
Samples type
Variable formula
Description
Sampling interval
Rising threshold
Falling threshold
When startup enables
This entry will exist : forever.
Latest value
Table 2-5 Description on the fields of the display rmon prialarm command
Prialarm table
owned by user1
VALID
Samples type
Variable formula
Description
Sampling interval
Rising threshold
: absolute
: .1.3.6.1.2.1.16.1.1.1.4.1
:
: 10(sec)
: 10000(linked with event 1)
: 2000(linked with event 1)
: risingOrFallingAlarm
: 0
Field
Index number of a line of the extended alarm table
Creator user 1
Valid
Sample type: change value or absolute value
Variable formula of the sampled node
Description
Sampling interval
Rising threshold. An alarm is triggered when the
rising threshold is reached
Huawei Technologies Proprietary
2-6
Chapter 2 RMON Configuration Commands
Description