Adjuncts and Peripherals
Terminal server installation
10
When administration is complete, from the Connections Menu, select logout (or press Ctrl D).
11
Close HyperTerminal.
At this point, you have established a connection path from the adjunct through the IOLAN+ to the
.
Testing
1
On the system management terminal, press Enter to get the login prompt to the Communication
Manager switch.
NOTE:
If you get garbled text, check the baud rate setting on the Port Setup Menu. You can
adjust it up or down.
2
If no login prompt appears, log back into the IOLAN+ through HyperTerminal.
3
Select Admin mode > stats and press Enter twice.
4
Select users and press Enter.
5
Look at the port that the adjunct is connected to and see if there is any traffic. If not, check all
your connections and administration fields.
** Administrator **
1. port1
2. port 2
3. port 3
4. port 4 modem
REM <unknown>
LOG
________________________________________________________________________________
Press <Enter> to see list of options.
IOLAN PLUS v4.02.00 a CDi
After you have successfully administered and validated the connection between the adjunct and the
through the IOLAN+, you can disconnect the laptop or other PC from the IOLAN+. No further IOLAN+
administration is required.
Potential failure scenarios and repair actions
If a link goes down between the terminal server and the switch, you must reboot the terminal server for
the link come back up. If you are performing a software upgrade or if a system reset occurs, you must
reboot the terminal server to restore the link. See
802
SERVER STATISTICS
Talking to host 172.22.22.67.5111<DSR+CTS+DCD >DTR+RTS
SERVER STATISTICS
waiting for DSR or DCD
waiting for DSR or DCD
logged out
logger not enabled
Rebooting the IOLAN+
Terminal: 2
<DSR+DCD >DTR+RTS
>DTR+RTS
>DTR+RTS
iolan-st
on page 799 for instructions.
SI Installation and Upgrades
June 2004