Signaling Configuration - Avaya MCC1 Installation And Upgrades

Media gateways installation and avaya definity server si upgrades made easy
Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

Figure 310: Typical nonsignaling wideband configuration
cydf049 RPY 123097
Figure notes
1
Wideband endpoint (wire per
manufacturer)
2
Modular cord
3
103A or modular wall jack
4
Channel service unit (CSU)
5
H600-307 cable to DTE connector on CSU
If using a CSU, the distance between connections may be up to 1300 ft. (397.2 m). The maximum
distance to the endpoint depends on the type of cable and the specifications of the endpoint.

Signaling configuration

A signaling connection from the system to a wideband endpoint passes through a bandwidth controller.
The distance between the system and the bandwidth controller depends on the type of cable and
controller.
Figure 311
SI Installation and Upgrades
June 2004
1
3
2
1
3
2
shows connections with and without a CSU.
Adjuncts and Peripherals
Wideband endpoints
4
AUX PORT COM PORT
MODEM
NETWORK
POWER
DTE
5
7
9
8
6
DS1/E1 circuit pack
7
Main distribution frame (MDF)
8
Distance limit depends on cable and
endpoint type.
9
A25D 25-pair cable (male-to-male)
6
6
809

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scc1

Table of Contents