2
At the MDF, connect jumper wires between 1 row/connecting block in the green field and up to 3
rows/connecting blocks in the purple field to concentrate the analog line pairs.
3
Connect an A25D cable between the sneak fuse panel and the 110-type terminal block connector
associated with the green row in Step 2.
4
Install a green label on the 110-type terminal block to identify the remote location.
5
Administer using the Administrator's Guide for Avaya Communication Manager (555-233-506).
Return to Task List
SI Installation and Upgrades
June 2004
Install and Administer Trunks
Add TN1654 DS1 Converter (r only)
691