Remote Test

Return to Task List
1
Call outside personnel who will be accessing the system remotely to perform administration,
maintenance, and testing.
2
Ask remote personnel to call system and login and display System Parameters Maintenance
screen. The login must be successful.
NOTE:
Product Identification on the System Parameters screen must match the Product
Identification administered by the local technician.
3
Have the remote personnel type
disconnect.
4
Have the remote personnel check the appropriate trouble ticket. The trouble ticket should show
"INADS,n,MINOR" in the description field to indicate a minor off-board alarm was reported to
the remote personnel. There may be more text in the description field if other resolved alarms
were reported.
5
Have the remote personnel make second call and log into the system and check the error log to
verify no problems. See Maintenance for Avaya DEFINITY® Server SI (555-23-123)
documentation for your system for error log and error code information.
6
Have the remote access personnel terminate logoff and disconnect.
Return to Task List

Local Test

Return to Task List
1
Log in as craft.
NOTE:
If you have a dadmin login and password, you can use them instead of craft and the craft
password.
2
Type
test inads-link
3
Request remote access personnel to verify that a trouble ticket was created.
4
Check error log to verify no problems.
5
Log off the system.

Test Basic Rate Interface

Return to Task List
SI Installation and Upgrades
June 2004
and press Enter, terminate the login, and
test inads-link
and press Enter.