Table 9: Required hardware for System 75 XE to R8si upgrade
Equipment
Description
J58890L
Enhanced Control Cabinet
J58890M
Enhanced Duplicated Control Cabinet
108595638
TN790B Processor
103557187
TN765 Processor Interface
PEC 6300-04X
Processor Port Network
J58890N
Expansion Control Cabinet
106647985
TN775C Maintenance
103557476
TN794 Network Control
848254942
TN794/TN2400 Network Control
103557294 or
TN776 or TN570D Expansion Interface 2 or 4
103281788
One type of:
One type of:
103557096
TN756 Tone-Detector
103557211
TN768 Tone-Clock
103557336
TN780 Tone-Clock
106706955
TN2182 Tone-Clock
H600-259 G1
Intercabinet Cables A, B, and C
103557252
TN772 Duplication Interface
405907015
WP-91716 L3 TDM/LAN Cable
105631527
AHF110 TDM/LAN Bus Terminator
R7/R8 Translations Card:
601817448
2 Mbyte Mass-Storage Translation Card
or
(white card) or
601817422
4 Mbyte Mass-Storage Translation Card
or
(white card) or
601817430
10 Mbyte Mass-Storage Translation
Card (white card)
63300A
FL2P-P-XX Fiber Cable
SI Installation and Upgrades
June 2004
System 75 XE to R8si (Blowback)
Task List: System 75 XE to R8si
Quantity
Notes
1
L-2 List 25 or newer uses TN794;
older carriers use TN794/TN2400
NetCon
1
Required for critical reliability
M-2 List 15 or newer uses TN794;
older carriers use TN794/TN2400
NetCon
1 or 2
One with standard reliability, two
with critical reliability.
1, 2, or 4
Provided as required for DCS, CMS,
AUDIX, etc.
1
EPN upgrade only
1
EPN upgrade only
1
EPN upgrade only
1 or 2
One with standard reliability, two
with critical reliability.
EPN upgrade only. 2 for std/high-
reliability. 4 for critical reliability.
TN570D required with optional
packet bus.
1 or 2
One with standard reliability, two
1 or 2
with critical reliability.
1 or 2
1
3
Required for critical reliability
2
Required for critical reliability
0 to 3
Quantity depends on the number of
single-carrier cabinets in the
upgraded PPN.
2
1 or 2
One with standard reliability, two
with critical reliability.
4-Mbyte translation memory cards
are required for a system that uses
recorded announcements. A 10
Mbyte card is required if a
DEFINITY Wireless Business
System is installed.
1 or 2
EPN upgrade only. 2 cables for
critical reliability systems.