Add Channel Service Units

Installing a 3150/3170 Channel Service Unit

H700-383 Cable Pin Assignments
Pin
Color
1
BK
2
Y
3
Shield
4
R
5
G
7
Shield
7
8
H700-383 Cable Lengths by Group Number
Group
Length
1
25 feet (7.7 m)
2
50 feet (15.2 m)
3
75 feet (22.9 m)
4
100 feet (30.5 m)
Installing a 3150/3170 Channel Service Unit
Figure 261, 3150/3170 Channel Service Unit Connections,
the H600-348quad cable to the CSU, through the H600-307 network cable, and to the network interface
through the smart jacks. The quad cable provides up to four connections using a 15-pin connector that
plugs into the DTE jack on each CSU. The H600-348 quad cable may require an adapter cable.
1
Install the CSU as shown in
655.
For some installations (such as a DS1 converter), use a Y-cable to connect the DEFINITY System
to the quad cable.
656 shows the
2
Label all cables.
654
Channel Service
Unit Designation
Line in 0
Line in 1
Line out 0
Line out 1
Group
5
7
7
8
Figure 261, 3150/3170 Channel Service Unit Connections,
Figure 262, DS1 Converter Connections Using Double-Headed cable,
Y Cable Lengths
on page 656.
Network
Designation
Function
R1
RCV
T1
R
XMT
T
Not assigned
Not assigned
Length
125 feet (38.1 m)
200 feet (71 m)
400 feet (122 m)
750 feet (198.1 m)
on page 655 shows a typical connection from
SI Installation and Upgrades
on page
on page
June 2004

Advertisement