Download Print this page
Avaya MCC1 Job Aid
Avaya MCC1 Job Aid

Avaya MCC1 Job Aid

Cabling guide
Hide thumbs Also See for MCC1:

Advertisement

Quick Links

Job Aid
Cabling Guide—MCC1 and SCC1 Media
Gateway
This cabling guide provides graphical representations on various cable connections for the Avaya MCC1
and SCC1 Media Gateways used in an S8700 Multi-Connect configuration. Different ribbon cables are
used and CAT5 Ethernet cables connect differently, depending on whether the carrier is a newer or older
version.
For newer carriers, A carrier position can be identified as J58890AF-2, L13 or higher list number and the
B carrier can be identified as J58890BB-4, L14 or higher (see page 2).
For older carriers, A carrier position can be identified as J58890AF-2, with a list number lower than L13
and the B carrier can be identified as J58890BB-4, with a list number lower than L14 (see page 3). For
some connectivity information, see page 4.
Although the graphic shows an IPSI in a second port network in a MCC1 Media Gateway with multiple
port networks, each port network does not require an IPSI circuit pack. One IPSI can control the whole
media gateway. However, when there are remote port networks, you may need to put IPSIs in more than
one port network in a media gateway to reach the minimum number of IPSIs required in an S8700 Multi-
Connect configuration.
Table 1, Cables used with the G650, MCC1, and SCC1 Media Gateways,
identification.
Table 1: Cables used with the G650, MCC1, and SCC1 Media Gateways
Comcode
601795495
601930639
700168727
700168735
700168834
Cabling Guide — MCC1 and SCC1 Media Gateway
555-245-771, Issue 2, June 2004
Job Aid Cabling Guide—MCC1 and SCC1 Media Gateway
Description
H600-204,G1—ICCA,B,C,D duplication ribbon cables (MCC1).Connectors
available only on a J58890AF-2, L13 expansion control carrier with AC1 L5
backplane (vertical Amphenol connectors).
H600-248, G1—ICCA,B duplication ribbon cables (SCC1).
Ribbon cable—from maintenance board to IPSI in MCC1 A carrier (migration only)
or SCC1 A media gateway
Ribbon cable—from maintenance board to IPSI in MCC1 B carrier (migration only)
Ribbon cable—from maintenance board to IPSI in SCC1 B media gateway
on page 1 shows the cable
1 of 2
1

Advertisement

loading

Summary of Contents for Avaya MCC1

  • Page 1 4. Although the graphic shows an IPSI in a second port network in a MCC1 Media Gateway with multiple port networks, each port network does not require an IPSI circuit pack. One IPSI can control the whole media gateway.
  • Page 2 Job Aid Cabling Guide—MCC1 and SCC1 Media Gateway Table 1: Cables used with the G650, MCC1, and SCC1 Media Gateways Comcode Description 700263502 IPSI Amphenol adapter (new installation only) Green CAT5 Ethernet cables 700170012 – 5-meter (16 feet) 700178056 – 25-meter (82 feet) 700178064 –...
  • Page 3 Job Aid Cabling Guide—MCC1 and SCC1 Media Gateway Wiring for Newer Carriers with CSS PNC MCC Single PN MCC Dual PN Legend Maintenance IPSI Control carrier = heavily Cable in front outlined carrier CAT5 cables Cable in back H600- 204,G1(2)
  • Page 4 Job Aid Cabling Guide—MCC1 and SCC1 Media Gateway Wiring for Older Carriers with CSS PNC MCC Single PN MCC Dual PN Legend Maintenance IPSI Control carrier = heavily Cable in front outlined carrier Cable in back CAT5 cables H600-204,G1 H600-204,G1...
  • Page 5 Job Aid Cabling Guide—MCC1 and SCC1 Media Gateway Wiring for Newer Carriers SERV SERV INTF INTF TERM TERM M IN Connecting to IPSI adapter Connecting ribbon cable (SCC1-high/critical) Connecting ICCA (MCC1) qrdsnwsp KLC 040804 Cabling Guide — MCC1 and SCC1 Media Gateway...
  • Page 6 Job Aid Cabling Guide—MCC1 and SCC1 Media Gateway Wiring for Older Carriers M IN M IN Connecting ribbon cable Connecting ribbon cable (duplex) (MCC1-high/critical) ALARMS EMER TR M IN AUTO Connecting ribbon cable Connecting to IPSI faceplate (SCC1-high/critical) (high/critical) qrdsmigr KLC 040804 Cabling Guide —...

This manual is also suitable for: