System 75 XE to R8si (Blowback)
Task List: System 75 XE to R8si
System
Steps
AC
DC
The results of system tests display on the monitor.
3
Verify that all tests pass.
If any of the terminal messages indicate a test has failed or if the message
displayed, refer to Maintenance for Avaya DEFINITY® Server SI (555-233-123) to clear the
trouble.
4
Type
set time
See
Figure
5
Enter the date information and the time in 24-hour format. Enter either
standard time
daylight saving time, set the value of Daylight Savings Rule to 0; otherwise, set
Daylight Savings Rule to 1. Press Enter to set the date and time and ensure that the
system boots properly.
Figure 70: Typical Date and Time Screen
DATE
Day of the Week: Tuesday
Day of the Month: 26
TIME
Hour: 20 Minute: 30
Daylight Savings Rule: 1
Return to Task List
274
1
Set the circuit breakers on the AC power panel to ON.
2
Set the cabinet circuit breakers to ON.
This starts the system initialization and test. All red LEDs
on the circuit packs go on and then off.
1
At the DC Battery Cabinet (if installed), set the circuit
breaker to ON.
2
At the DC Power Cabinet, set the circuit breaker(s) on the
rectifiers to ON.
This starts the system initialization and test. Some red
LEDs may be turned on, but they are turned off during the
boot-up process. No action is required.
and press Enter.
70.
, depending on the current time in your time zone. If your area does not use
DATE AND TIME
Month: June
Year: 2000
Second: XX
Type: standard
SI Installation and Upgrades
is
spe down mode
or
daylight saving time
June 2004