Adjuncts and Peripherals
Call detail recording (CDR)

Administering CDR parameters

You must administer CDR parameters to let the system know that the adjunct is connected through
TCP/IP. For details on all fields on the CDR System Parameters screen, see Administrator's Guide for
Avaya Communication Manager (555-233-506).
1
Type change system-parameters cdr and press Enter.
The CDR System Parameters screen appears.
change system-parameters cdr
Node Number (Local PBX ID):
Primary Output Format: unformatted
Secondary Output Format: unformatted Secondary Output Endpoint: CDR2
Use Enhanced Formats? n
Modified Circuit ID Display? n
Suppress CDR for Ineffective Call Attempts? y
Disconnect Information in Place of FRL? n
Force Entry of Acct Code for Calls Marked on Toll Analysis Form? n
Record Called Vector Directory Number Instead of Group or Member? n
Record Called Agent Login ID Instead of Group or Member? n
Inc Trk Call Splitting? n
Record Non-Call-Assoc TSC? n
Record Call-Assoc TSC? n
Privacy - Digits to Hide: 0
2
In the Primary Output Format field, enter a format specific to the call accounting system,
if necessary. In the example,
you would use
3
In the Primary Output Endpoint field, type CDR1.
4
If you use a secondary output device, and that device is also connected through TCP/IP, complete
the Secondary Output Format field. Also, type CDR2 in the Secondary Output
Endpoint field.
5
Press Enter to save your changes.

Testing the switch-to-adjunct link

You can use the test, status, busyout and release commands to find and correct problems with CDR links.
For more information about these commands, see the Maintenance manual for your switch.
status cdr-link
Link State: up
Maintenance Busy? no
Work with the vendor to test the link from the call accounting adjunct.
806
CDR SYSTEM PARAMETERS
Use ISDN Layouts? n
Record Outgoing Calls Only? y
Digits to Record for Outgoing Calls: dialed
unformatted
.
printer
CDR LINK STATUS
Primary
CDR Date Format: month/day
Primary Output Endpoint: CDR1
EIA Device Bit Rate: 9600
Condition Code 'T' for Redirected Calls? n
Remove # From Called Number? n
CDR Call Splitting? y
Attendant Call Recording? y
Interworking Feat-flag? n
Calls to Hunt Group - Record: member-ext
CDR Account Code Length: 4
is used. If you were sending data directly to a printer,
Secondary
extension not administered
SI Installation and Upgrades
Page
1 of
1
Intra-switch CDR? n
June 2004