Avaya MCC1 Installation And Upgrades page 234

Media gateways installation and avaya definity server si upgrades made easy
Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

System 75 XE to R8si (Blowback)
Task List: System 75 XE to R8si
Three -48 VDC power sources for remotely powering 3 attendant consoles or telephone adjuncts.
The remote management terminal interface trunk connection location.
Access to a relay contact is available to actuate a customer-provided light, bell, or similar alarm
device. Administer the system to make contact when a major, minor or warning alarm condition
occurs in the system. The circuitry required for this feature is customer-provided. The device
connected to the alarm leads must not exceed a rating of 30 VAC RMS or 60 VDC at 0.75 amps.
A 25-pair connector labeled AUX is provided on the rear of the control carrier. Connect a cable to this
connector and route to a connecting block on the trunk/auxiliary field.
Auxiliary lead appearances at AUX connector
Color
W-BL
BL-W
W-O
O-W
W-G
G-W
W-BR
BR-W
W-S
S-W
R-BL
BL-R
R-O
O-R
R-G
G-R
R-BR
BR-R
R-S
S-R
234
Pin number
AUX connector outputs
26
Major
1
(Note 1)
27
Minor
2
(Note 1)
28
3
GND
29
4
GND
30
5
GND
31
6
GND
32
7
GND
33
N/C
8
34
N/C
9
35
N/C
10
SI Installation and Upgrades
June 2004