Install Additional Hardware

Administer TN464GP/TN2464BP with Echo Cancellation

Administer DCS (Add DCS)
Return to Task List
1
Administer the required translation data using the screens listed under Distributed
Communications System (DCS) in the Administrator's Guide for Avaya™ Communication
Manager.
Save Translations (Add DCS)
Return to Task List
1
If the system is high- or critical-reliability, type
standby SPE is refreshed and that the standby disk is in service.
2
Type
save translation
to take all translation information in memory and write it to the disk(s).
Administer TN464GP/TN2464BP with Echo
Cancellation
Return to Task List
This section provides information about the TN464GP and TN2464BP circuit packs with echo
cancellation and the procedure to
The TN464GP and TN2464BP circuit packs with echo cancellation are intended for DEFINITY
customers who are likely to encounter echo over circuits connected to the Direct Distance Dialing (DDD)
network. These circuit packs are intended for channels supporting voice; therefore, they support the
following trunks: CAS, CO, DID, DIOD, DMI, FX, Tie, WATS. They do not support any data trunk
groups.
NOTE:
The P suffix designation means the circuit pack is programmable; new firmware can be
downloaded directly to the circuit pack. For more information, see
Programmable Circuit Packs
The TN464GP and TN2464BP circuit packs are backwards compatible, although the echo cancellation
feature can be used only with Release 1.1 or later of Avaya™ Communication Manager and after the
feature is enabled.
The echo cancellation feature cancels echoes with delays up to 96 ms. Echo cancellation is disabled
automatically when the circuit pack detects a 2100-Hz phase-reversed tone put out by high-speed
modems (56 kbaud) but not when it detects a 2100-Hz straight tone generated by low-speed modems (9.6
kbaud).
For information on installing port circuit packs, see
on setting the option switches, see
Echo cancellation must first be purchased, then added to the system via a new License File.
Return to Task List
598
status spe
[
spe-a or both
]
disk
and press Enter. This command instructs the system
Administer TN464GP/TN2464BP
on page 715.
Add Port Circuit Packs
Option Switch Settings
and press Enter to verify that the
on page 599.
Upgrade Firmware on
on page 567. For information
on page 741.
SI Installation and Upgrades
June 2004

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scc1

Table of Contents