Avaya MCC1 Installation And Upgrades page 554

Media gateways installation and avaya definity server si upgrades made easy
Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

Install and Wire Telephone Power Supply
Important Warning for 1145B Power Supply
Discard discharged batteries as soon as possible. Discharged batteries are more likely to leak.
Do not store batteries in high temperature areas. Batteries stored in a cold environment should be
protected from condensation during storage and warming. Batteries should be stabilized at room
temperature prior to use after cold storage. Do not install batteries if the manufacturing date on the
label indicates that the batteries are more than six months old.
Return to Task List
Install the Wall-Mounting Plates
Return to Task List
The top plate is used for mounting the back-up battery. The bottom plate is used to mount the power
supply and distribution units. The plates can be rack-mounted using standard rack-mounting brackets.
See
Figure 220, 1145B/1146B Mounting Arrangement,
1
Locate one plate directly below the other one such that the AC power cord (6.5 feet or 2 meters)
reaches the electrical outlet from a power supply mounted on the bottom plate. Both plates should
be located so the raised letters are right side up.
NOTE:
A maximum of four power supplies can be powered from one dedicated 110 VAC, 20 amp
(or 230 VAC, 15 amp) feeder. Use only unswitched receptacles (receptacles not connected
to a wall switch).
2
Secure the wall mounting plates to a standard 3/4 inch (2 cm) thick plywood mounting board.
Each mounting plate comes with four #10 x 1/2-inch wood screws.
3
The 1145B Power Supply is snap-fit onto the bottom wall mounting plate without tools.
4
An installer-provided insulated ground wire, 16 AWG (#12) (1.2 mm
connect the power supply frame ground lug to an approved ground. The frame ground screw is
located next to the AC receptacle, to the left of the unit.
5
Mark the Unit Number and Connectivity information on the front label next to the LEDs.
554
on page 555.
2
) or greater, is required to
SI Installation and Upgrades
June 2004

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scc1

Table of Contents