Check Circuit Pack Configuration - Avaya MCC1 Installation And Upgrades

Media gateways installation and avaya definity server si upgrades made easy
Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

Figure 182: Sample System Status Screen for Cabinet 2 (Page 2 of 3)
status system all-cabinets
SPE
MODE
1A
active
1B
maint/init
SERVICE
CONTROL
TDM
STATE
CHANNEL
2A
in
2B
in
EMERGENCY
TRANSFER
2A
Return to Task List

Check Circuit Pack Configuration

Return to Task List
The list configuration report provides a list of circuit packs connected to the system and recognized by
the software.
1
Type
list configuration all
2
Verify the screen displays list configuration similar to
Screen — Page 1,
(except power supply circuit packs). Do not attempt to correct any problems until after the
diagnostic tests that you run later in the system tests.
3
Note any boards with a VINTAGE column entry of NO BOARD or CONFLICT.
NOTE:
A u indicates unassigned ports, and a number indicates the port has been translated.
SI Installation and Upgrades
June 2004
SYSTEM STATUS CABINET 2
SELECT
SPE ALARMS
SWITCH
MAJOR MINOR
auto
0
auto
0
DEDICATED
TONES
PKT
y
n
2
n
y
SELECT
SWITCH
EXP-LINK
auto-on
01A01-02A01
01B01-02B02
and press Enter.
on page 490. Make sure the software is communicating with each circuit pack
Page
TONE/
SERVICE SYSTEM
CLOCK
STATE
CLOCK
0
2A
in
0
2B
in
SERVICE
BUS ALARMS
STATE
MAJOR MINOR
SERVICE
CABINET
STATE
MODE
TYPE
in
standby
MCC
in
active
Figure 183, Sample System Configuration
Test the System
LED Indicators
2 of
3
SPE A
SYSTEM
TONE
active
active
standby standby
BUS
OPEN BUS
FAULTS LEADS
489

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scc1

Table of Contents