PC connections by platform
Reliability
Standard
High/Critical
Return to Task List
Connect Remotely to the Avaya Media Gateway Through a Data Module
Return to Task List
If the PC is more than 50 ft (15 m) from the Avaya Media Gateway, you can connect it through a data
module.
1
Connect the equipment as shown in
(top) or 7400B (bottom) data module, on page
NOTE:
With a 7400A or 7400B+ data module, use a 4-wire digital line circuit pack. With the
8400B+ data module, use a 2-wire digital line circuit pack.
In place of a 7400B+ data module, you can use a 7400A data module. If you do, see
the Data Module to DCE Mode on page
2
Wire the digital line circuit pack to the wall jack as follows:
— For a 7400B+, wire to the second and third pair of the wall jack.
— For an 8400B+, wire to the first pair of the wall jack.
After connecting the data module, check the
any necessary tasks.
Return to Task List
SI Installation and Upgrades
June 2004
r
si
Terminal Active
TERM
DOT
Figure 168, A typical remote connection using an 8400B
456.
458.
Set the Data Module to DCE Mode on page 458
Bring the System Online
Task List: Make Data Module Settings
csi
TERM
and perform
Set
455