Install and Wire Telephones
Task List: Connect Voice and Data Terminals
Figure 193: 400B2 Adapter Connecting to a Modular Plug
Figure notes
1
Flush-Mounted Information Outlet
2
Surface-Mounted Information Outlet
3
To Individual Power Unit
Return to Task List
Connect an Analog Station or 2-Wire Digital Station
Return to Task List
This example is typical of the 2-wire digital stations (603E, 84xx, 94xx, 302C1),
2-wire analog stations (500, 2500, 71xx), analog Central Office (CO) trunks, Direct Inward Dial (DID)
trunks, and external alarms. See
1
Choose a peripheral to connect (such as a 2-wire digital station).
2
Choose the port circuit pack to use and its carrier and slot number (from
Pack and Telephone Pin Designations,
1, Carrier C, Slot 1.
3
Choose a port circuit on the port circuit pack, for example port 3.
4
Install cross-connect jumpers to connect the pins from the 2-wire digital station to the appropriate
pins on the port circuit pack.
5
Administer using Administrator's Guide for Avaya Communication Manager (555-233-506).
504
4
400B2 Adapter
5
To Telephone
6
Destination Service Access Point
(DSAP) Power Cord
Figure 194, 2500-Type Analog Telephone Wiring,
on page 505). For example: TN2183 Analog Line, Cabinet
r749428 KLC 060396
on page 505.
Table 20, Port Circuit