Test the C-LAN Connection

Return to Task List
To test the external IP connections, ping the C-LAN circuit pack and ping a known computer connected
to your network. If everything is configured correctly, the Result column on the Ping Results screen
reads
. If it reads
PASS
cabling.
1
To ping the C-LAN server, type
Enter.
The variable
is the cabinet, carrier, and slot of the TN799x C-LAN circuit pack.
2
Type
ping ip-address nnn.nnn.nnn.nnn board UUCSS
The variable
UUCSS
The TN799x C-LAN circuit pack is now installed in the DEFINITY carrier and connected to the IP
network.
Return to Task List

Test Stratum 3 Clock (if used)

Return to Task List
SI Installation and Upgrades
June 2004
Test Features
9 seconds of 1004 Hz tone at 0 dB
1 second of silence
Cycle is repeated until disconnect, which is forced after 24 hours
9 seconds of 1004 Hz tone at -16 dB
1 second of silence
9 seconds of 404 Hz tone at -16 dB
1 second of silence
9 seconds of 2804 Hz tone at -16 dB
30 seconds of silence
0.5 seconds of test progress tone (2225 Hz)
About 5 seconds of silence
Forced disconnect
, verify the IP-address information and check the connectivity, including the
ABORT
ping ip-address nnn.nnn.nnn.nnn board UUCSS
is the IP address of the TN799x C-LAN circuit pack and UUCSS
nnn.nnn.nnn.nnn
is the IP address of another computer beyond the gateway and
nnn.nnn.nnn.nnn
is the cabinet, carrier, and slot of the TN799x C-LAN circuit pack.