Analog Tie Trunk Example - Avaya MCC1 Installation And Upgrades

Media gateways installation and avaya definity server si upgrades made easy
Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

Install and Wire Telephones

Analog Tie Trunk Example

Analog Tie Trunk Example
Return to Task List
This example shows how to connect analog tie trunk wiring from one DEFINITY System to another
DEFINITY System.
1
Set the option switches on the port circuit pack (such as TN760E).
Go to
Option Switch Settings
2
Install cross-connect jumpers to connect the pins from the tie trunk circuit pack to the appropriate
leads on the external tie trunk.
Figure 195, Analog Tie Trunk Wiring,
connected to a DEFINITY System tie trunk. Names of the tie trunk leads must be determined
from the manufacturer or supplier of the external trunk circuit.
3
Administer on the Trunk Group Screen of the management terminal. Refer to the Administrator's
Guide for Avaya Communication Manager (555-233-506) for more details.
Figure 195: Analog Tie Trunk Wiring
Figure notes
1
External Trunk or Adapter
Return to Task List
506
on page 741 for detailed information.
on page 506 shows a DEFINITY System tie trunk
T.1
26
R.1
1
T1.1
27
R1.1
2
E.1
28
M.1
3
2
Tie Trunk Circuit Pack (Position 1C05)
T.2
29
4
R.2
T1.2
30
R1.2
5
31
E.2
6
M.2
tie_wire RBP 071796
SI Installation and Upgrades
June 2004

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scc1

Table of Contents