Avaya MCC1 Installation And Upgrades page 541

Media gateways installation and avaya definity server si upgrades made easy
Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

Figure 211: Connections for Telephone Used for Emergency Transfer and as Normal
Extension
2820
Figure notes
1
To Network Interface Facility
2
To Blue or White Station Distribution
Field
3
To TN2183 or Equivalent Analog Line
Circuit Pack
Return to Task List
Install Telephones Used Only for
Emergency Transfer (Trunk/Auxiliary Field)
Return to Task List
1
Connect a pair of wires between the -48V and GRD terminals on the yellow emergency transfer
row/connecting block and the EM TRANS RELAY PWR terminal. See
for Telephone Used for Emergency Transfer,
2
Connect Central Office (CO) trunk leads from the purple field to TC terminals on the yellow
emergency transfer row/connecting block for each trunk.
3
Connect CO trunk leads from the green field to TK terminals on the yellow emergency transfer
row/connecting block for each trunk.
4
Connect ST leads on the yellow emergency transfer row/connecting block for each emergency
transfer telephone to the assigned terminal in the blue or white station distribution field. The ST
terminal leads should be terminated on the following pairs: 1, 4, 7, 10, 13, 16, 19, or 22 (the first
pair of any 3-pair group).
SI Installation and Upgrades
June 2004
Task List: Typical Emergency Transfer Panel and Telephone Installation
10
35
3
4
5
TC
TK
LC
ST
TC
TK
LC
ST
TC
TK
1M
1m
2M
2m
3M
3m
3w
ALARM MONITORS
ST
ST
EMXR
7
6
7
8
LC
ST
TC
TK
LC
ST
TC
TK
LC
ST
EM TRANS RELAY PWR
ACC PWR
4
To TN747B (or Equivalent) Central
Office Trunk Circuit Pack
5
To Power Transfer Unit
6
To Control Carrier AUX Connector
on page 542.
Install and Wire Telephones
C
C
C
N
N
N
N
N
G
O
O
O
-48
O
C
C
O
C
R
M
M
M
1
2
1
2
3
D
V
1
2
3
r758582b MMR 042996
Figure 212, Connections
541

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scc1

Table of Contents