37.3 The Tca Configuration Screen

Use this screen to configure thresholds for the (Threshold-Crossing Alarms) TCA profile. Click Tca
Configuration in the Advanced Application > OLT Registration screen to display the screen as shown.
The OLT will send threshold-crossing alarms to an ONT if the ONT's parameters go beyond the thresholds
configured here.
Figure 181 Advanced Application > OLT Registration > Tca Configuration
The following table describes the labels in this screen.
Table 128 Advanced Application > OLT Registration > Tca Configuration
LABEL
Tca Active
AID
FEC
Corrected
Byte
Threshold
FEC
Corrected
Code Word
Threshold
FEC
Uncorrected
Code Word
Threshold
BIP byte
Threshold
BIP error
Threshold
Chapter 37 OLT Registration
DESCRIPTION
Click Delete to remove the profiles with the Delete option selected.
Click Cancel to begin configuring the screen again.
DESCRIPTION
Select this to enable low rate Threshold Crossing Alert (TCA) alarm.
Enter the identifier for the ONT that you want the settings configured here to apply to.
Enter the threshold of corrected bytes that can be received in the Forward Error Correction (FEC)
process.
Enter the threshold of corrected codewords that can be received in the Forward Error Correction
(FEC) process.
Enter the threshold of codewords that can be received without being corrected in the Forward
Error Correction (FEC) process.
Enter the threshold of Bit Interleaved Parity (BIP) bytes that can be received.
Enter the threshold of Bit Interleaved Parity (BIP) errors that are allowed.