Frame Ground Cable Specifications - ZyXEL Communications OLT2406 User Manual

2u temperature-hardened, 6-slot mini chassis gpon olt
Table of Contents

Advertisement

Table 386 System Specifications (continued)
Power module
Certifications

110.2 Frame Ground Cable Specifications

The following table lists the specifications of the frame ground cable.
Table 387 Frame Ground Cable Specifications
ITEM
Type
Connectors
Wire gauge
Chapter 110 Product Specifications
DC Input
Voltage range:-36 to -72 V DC, normal -48 V input (there is no tolerance for the DC
input voltage)
Max. Input DC Current: 185 Watts; 5.2 Amps
DC Output
Voltage: 12 V
Built-in surge protection
Non-destructive protection: -36 to -72 V DC
RoHS and WEEE compliant
Safety
IEC62368-1
EN62368-1
CSA60950-1
EN60950-1
UL60950-1
IEC60950-1
EMC
FCC Part 15 Class A
EN 55022
EN 55024
DESCRIPTION
Electrical cable
cable terminal, gauge 4 mm recommended
AWG (American Wire Gauge) is a measurement system for wire that specifies its
thickness. As the thickness of the wire increases, the AWG number decreases.
Make sure you use wires of the specified wire gauge.
14 AWG, go up 1 gauge for a distance of more than 10 feet
OLT2406 User's Guide