Table 348 OLT Configuration Commands (continued)
COMMAND
no O7-state <sn>
no inactive
no ont-template
no ranging-distance
ont-template
ranging-distance <max>
register-method A
register-method C
register-method C-autolock
register-method D
register-method E
Chapter 93 OLT Configuration
DESCRIPTION
Disables Emergency Stop State (07) on the ONT
with the specified serial number.
: ONT serial number, 16 characters.
sn
Enables the OLT PON port.
Disables the ONT template.
Resets the ranging distance to default.
Enables the ONT template.
Configures the maximum ranging distance.
: The maximum distance is between 20 to 60
max
km
Sets the OLT PON port's register method to A.
Requires the serial number and password the
ONT sends to match the ones you configure on
the OLT.
Sets the OLT PON port's register method to C.
Requires either one of the following items that
the ONT sends to match what you configure on
the OLT.
GPON password
ONT serial number
Sets the OLT PON port's register method to C-
autolock.
Requires the serial number the ONT sends to
match the one you configure on the OLT.
Sets the OLT PON port's register method to D.
Automatically registers the ONT by template
(onu-121~128) and brings it into service without
checking the serial number or password.
The ONT registered with format D will lose the
template settings when it's not connected to
the OLT. If the ONT is discovered the next time,
the OLT will apply the template according to the
settings configured in the Advanced Application
> OLT Registration screen automatically.
Sets the OLT PON port's register method to E.
Automatically registers the ONT by template
(onu-121~128) and brings it into service without
checking the serial number or password.
The ONT registered with format E will keep the
template settings even when the it's not
connected to the OLT. If the ONT is discovered
the next time, it has the template settings
already, so the OLT won't apply the template
again.