Figure 276 Switch in Loop State
N
The loop guard feature checks to see if a loop guard enabled port is connected to a switch in loop
state. This is accomplished by periodically sending a probe packet and seeing if the packet returns on
the same port. If this is the case, the OLT will shut down the port connected to the switch in loop state.
The following figure shows a loop guard enabled port N on switch A sending a probe packet P to switch
B. Since switch B is in loop state, the probe packet P returns to port N on A. The OLT then shuts down port
N to ensure that the rest of the network is not affected by the switch in loop state.
Figure 277 Loop Guard - Probe Packet
The OLT also shuts down port N if the probe packet returns to switch A on any other port. In other words
loop guard also protects against standard network loops. The following figure illustrates three switches
forming a loop. A sample path of the loop guard probe packet is also shown. In this example, the probe
packet is sent from port N and returns on another port. As long as loop guard is enabled on port N. The
OLT will shut down port N if it detects that the probe packet has returned to the OLT.
Figure 278 Loop Guard - Network Loop
A
Note: After resolving the loop problem on your network you can re-activate the disabled port
(see
Section 54.10 on page
Chapter 80 Loop Guard
A
A
P
N
N
P
421).