SNMP Traps
The OLT sends traps to an SNMP manager when an event occurs. The following tables outline the SNMP
traps by category.
An OID (Object ID) that begins with "1.3.6.1.4.1.890.1.5.17" is defined in private MIBs. Otherwise, it is a
standard MIB OID.
The OIDs beginning with "1.3.6.1.4.1.890.1.5.17.5" are specific to OLT1404.
The OIDs beginning with "1.3.6.1.4.1.890.1.5.17.6" are specific to OLT1408.
Table 174 SNMP System Traps
OPTION
OBJECT LABEL
coldstart
coldStart
warmstart
warmStart
fanspeed
FanSpeedEventOn
FanSpeedEventClear
temperature
TemperatureEventOn
TemperatureEventClear
voltage
VoltageEventOn
VoltageEventClear
reset
UncontrolledResetEventOn
ControlledResetEventOn
RebootEvent
RTCNotUpdatedEventOn
timesync
RTCNotUpdatedEventClear
intrusionlock
IntrusionLockEventOn
loopguard
LoopguardEventOn
Chapter 44 Access Control
OBJECT ID
1.3.6.1.6.3.1.1.5.1
1.3.6.1.6.3.1.1.5.2
1.3.6.1.4.1.890.1.5.17.5.31.2.1
1.3.6.1.4.1.890.1.5.17.6.31.2.1
1.3.6.1.4.1.890.1.5.17.5.31.2.2
1.3.6.1.4.1.890.1.5.17.6.31.2.2
1.3.6.1.4.1.890.1.5.17.5.31.2.1
1.3.6.1.4.1.890.1.5.17.6.31.2.1
1.3.6.1.4.1.890.1.5.17.5.31.2.2
1.3.6.1.4.1.890.1.5.17.6.31.2.2
1.3.6.1.4.1.890.1.5.17.5.31.2.1
1.3.6.1.4.1.890.1.5.17.6.31.2.1
1.3.6.1.4.1.890.1.5.17.5.31.2.2
1.3.6.1.4.1.890.1.5.17.6.31.2.2
1.3.6.1.4.1.890.1.5.17.5.31.2.1
1.3.6.1.4.1.890.1.5.17.6.31.2.1
1.3.6.1.4.1.890.1.5.17.5.31.2.1
1.3.6.1.4.1.890.1.5.17.6.31.2.1
1.3.6.1.4.1.890.1.5.1.1.2
1.3.6.1.4.1.890.1.5.17.5.31.2.1
1.3.6.1.4.1.890.1.5.17.6.31.2.1
1.3.6.1.4.1.890.1.5.17.5.31.2.2
1.3.6.1.4.1.890.1.5.17.6.31.2.2
1.3.6.1.4.1.890.1.5.17.5.31.2.1
1.3.6.1.4.1.890.1.5.17.6.31.2.1
1.3.6.1.4.1.890.1.5.17.5.31.2.1
1.3.6.1.4.1.890.1.5.17.6.31.2.1
OLT2406 User's Guide
364
DESCRIPTION
This trap is sent when the OLT is turned on.
This trap is sent when the OLT restarts.
This trap is sent when the fan speed goes
above or below the normal operating
range.
This trap is sent when the fan speed returns
to the normal operating range.
This trap is sent when the temperature goes
above or below the normal operating
range.
This trap is sent when the temperature
returns to the normal operating range.
This trap is sent when the voltage goes
above or below the normal operating
range.
This trap is sent when the voltage returns to
the normal operating range.
This trap is sent when the OLT automatically
resets.
This trap is sent when the OLT resets by an
administrator through a management
interface.
This trap is sent when the OLT reboots by an
administrator through a management
interface.
This trap is sent when the OLT fails to get the
time and date from a time server.
This trap is sent when the OLT gets the time
and date from a time server.
This trap is sent when intrusion lock occurs
on a port.
This trap is sent when loopguard shuts down
a port.