Technical Reference; Dhcp Snooping Overview - ZyXEL Communications OLT2406 User Manual

2u temperature-hardened, 6-slot mini chassis gpon olt
Table of Contents

Advertisement

Figure 144 Advanced Application > IP Source Guard > ARP Inspection > Configure > VLAN
The following table describes the labels in this screen.
Table 92 Advanced Application > IP Source Guard > ARP Inspection > Configure > VLAN
LABEL
VLAN
Start VID
End VID
Apply
VID
Enabled
Log
Apply
Cancel

27.10 Technical Reference

This section provides technical background information on the topics discussed in this chapter.

27.10.1 DHCP Snooping Overview

Use DHCP snooping to filter unauthorized DHCP packets on the network and to build the binding table
dynamically. This can prevent clients from getting IP addresses from unauthorized DHCP servers.
Chapter 27 IP Source Guard
DESCRIPTION
Use this section to specify the VLANs you want to manage in the section below.
Enter the lowest VLAN ID you want to manage in the section below.
Enter the highest VLAN ID you want to manage in the section below.
Click this to display the specified range of VLANs in the section below.
This field displays the VLAN ID of each VLAN in the range specified above. If you configure the
* VLAN, the settings are applied to all VLANs.
Select Yes to enable ARP inspection on the VLAN. Select No to disable ARP inspection on the
VLAN.
Specify when the OLT generates log messages for receiving ARP packets from the VLAN.
None: The OLT does not generate any log messages when it receives an ARP packet from the
VLAN.
Deny: The OLT generates log messages when it discards an ARP packet from the VLAN.
Permit: The OLT generates log messages when it forwards an ARP packet from the VLAN.
All: The OLT generates log messages every time it receives an ARP packet from the VLAN.
Click Apply to save your changes to the OLT's run-time memory. The OLT loses these changes
if it is turned off or loses power, so use the Save link on the top navigation panel to save your
changes to the non-volatile memory when you are done configuring.