Figure 167 Advanced Application > ONT VoIP > Voip-Dial-Plan
The following table describes the labels in this screen.
Table 115 Advanced Application > ONT VoIP > Voip-Dial-Plan
LABEL
DESCRIPTION
Name
Specify a name for the profile of dial plans.
max-size
Specify the maximum number (from 1 to 256) of dial plans.
critical-dial-
Specify the critical dial timeout (from 0 to 8000) in milliseconds.
timeout
If you have a dial plan, the ONT uses a digit map internally to represent the number and type of digits
it expects according to the dial plan. The ONT uses the inter-digit timer when checking a string of
dialed digits for matches with the digit map. The ONT starts the inter-digit timer when a subscriber
dials the first digit and restarts it after each new digit dialed until there is a digit map match or
mismatch.
The inter-digit timeout uses the partial digit timeout's value when at least one more digit is needed to
match any of the digit map's patterns. If the string of dialed digits already matches a digit map, the
ONT waits for the critical dial timeout period to make sure the next dialed digit does not cause a
mismatch.
If you do not have a dial plan, the ONT uses the value of the critical dial timeout for the inter-digit
timer.
partial-dial-
Specify the partial dial timeout (from 0 to 32000) in milliseconds.
timeout
format
Select the format:
not-def: Not defined
h248: H.248 format with specific plan (table entries define the dialing plan)
NSC: NSC format
ven-spe: Vendor specific format