Table 55 Advanced Application > Port Authentication > MAC Authentication (continued)
LABEL
DESCRIPTION
Timeout
Specify the amount of time before the OLT allows a client MAC address that fails
authentication to try and authenticate again. Maximum time is 3000 seconds.
When a client fails MAC authentication, its MAC address is learned by the MAC address table
with a status of denied. The timeout period you specify here is the time the MAC address entry
stays in the MAC address table until it is cleared. If you specify 0 for the timeout value, the OLT
uses the Aging Time configured in the Switch Setup screen.
Note: If the Aging Time in the Switch Setup screen is set to a lower value, then it
Port
This field displays the port number.
See
Table 29 on page 120
*
Use this row to make the setting the same for all ports. Use this row first and then make
adjustments on a port-by-port basis.
Note: Changes in this row are copied to all the ports as soon as you make them.
Active
Select this check box to permit MAC authentication on this port. You must first allow MAC
authentication on the OLT before configuring it on each port.
Apply
Click Apply to save your changes to the OLT's run-time memory. The OLT loses these changes if
it is turned off or loses power, so use the Save link on the top navigation panel to save your
changes to the non-volatile memory when you are done configuring.
Cancel
Click Cancel to begin configuring this screen afresh.
Chapter 19 Port Authentication
supersedes this setting. See
for more detailed information.
OLT2406 User's Guide
170
Section 8.5 on page
100.