This example shows the current alarm LED status for each slot in the OLT. It also lists the type of alarm
detected when the alarm LED is on.
OLT2406# show alarm-status
table_size=6, alarmMask= Voltage, Temperature, Fan, Ext Alarm, SFP, 48V
Fault
index
name
AlmLED
-----
-----
------
----
1
msc
ON
2
ge-3
OFF
3
ge-4
OFF
4
ge-5
OFF
5
ge-6
OFF
6
fan
OFF
This example shows the current and recent CPU utilization.
OLT2406# show cpu-utilization
CPU usage status:
baseline 1715384 ticks
sec
ticks
util sec
util
--- ------- ------ --- ------- ------ --- ------- ------ --- -------
0
657543
61.67
63.85
4
195580
88.60
70.36
--------------------------------- SNIP ---------------------------------
The following table describes the labels in this display.
Table 334 show cpu-utilization
LABEL
DESCRIPTION
baseline
This field displays the number of CPU clock cycles per second.
sec
This field displays the historical interval.
Interval 0 is the time starting one second ago to the current instant.
Interval 1 is the time starting two seconds ago to one second ago.
Interval 2 is the time starting three seconds ago to two seconds ago.
ticks
This field displays the number of CPU clock cycles the CPU was not used during the interval.
util
This field displays the CPU utilization during the interval.
util = [(baseline - ticks) / baseline] * 100
Chapter 86 Diagnostics
AlmItem(s)
------------------------------------------------
SFP
-
-
-
-
-
ticks
util sec
1
255118
85.13
2
5
791000
53.89
6
OLT2406 User's Guide
631
ticks
util sec
ticks
394329
77.01
3
620008
137625
91.98
7
508456