ZyXEL Communications OLT2406 User Manual page 662

2u temperature-hardened, 6-slot mini chassis gpon olt
Table of Contents

Advertisement

Table 352 Remote ONT Commands (continued)
COMMAND
option82 circuit-id option-
info <info>
no option82 circuit-id
Chapter 96 Remote ONT
DESCRIPTION
Configures the DHCP option 82 circuit ID format.
The maximum length is 127 characters.
Note: When information is transformed to
circuit ID, the result will be shortened
to 127 characters.
: DHCP option82 circuit ID info is
info
composed of the following special characters
except % and space, that is ~`!@#$^&*()-
=_+{}<>?,./
: equals character %
%%
: equals character space
%space
: client source mac
%mac
: host device name
%hname
: slot index of the logic port
%slotid
: PON port index
%pid
: ONT index
%oid
: ONT card index
%ocid
: UNI port index
%upid
: SVLAN ID on network-network
%nnisvlan
interface
: SVLAN ID on service-network
%snisvlan
interface
: CVLAN ID on service-network
%snicvlan
interface
: serial number of remote ONT
%sn
: shelf ID
%shelf
: rack ID
%rack
Note: For PON ports, the OLT uses the
following rules for DHCP option 82
configuration: (1) per system's
format > (2) per ONT's option-info >
(3) per system's option and
information
Disables DHCP option 82 circuit ID.
OLT2406 User's Guide