ZyXEL Communications OLT2406 User Manual page 612

2u temperature-hardened, 6-slot mini chassis gpon olt
Table of Contents

Advertisement

An OID (Object ID) that begins with "1.3.6.1.4.1.890.1.5.17" is defined in private MIBs. Otherwise, it is a
standard MIB OID.
The OIDs beginning with "1.3.6.1.4.1.890.1.5.17.4" are specific to the OLT2406.
Table 318 SNMP System Traps
OPTION
OBJECT LABEL
coldstart
coldStart
warmstart
warmStart
fanspeed
FanSpeedEventOn
FanSpeedEventClear
temperature
TemperatureEventOn
TemperatureEventClear
voltage
VoltageEventOn
VoltageEventClear
reset
UncontrolledResetEventOn
ControlledResetEventOn
RebootEvent
timesync
RTCNotUpdatedEventOn
RTCNotUpdatedEventClear
intrusionlock
IntrusionLockEventOn
loopguard
LoopguardEventOn
Table 319 SNMP Interface Traps
OPTION
OBJECT LABEL
linkup
linkUp
LinkDownEventClear
Chapter 85 Access Control
OBJECT ID
1.3.6.1.6.3.1.1.5.1
1.3.6.1.6.3.1.1.5.2
1.3.6.1.4.1.890.1.5.17.4.31.2.1
1.3.6.1.4.1.890.1.5.17.4.31.2.2
1.3.6.1.4.1.890.1.5.17.4.31.2.1
1.3.6.1.4.1.890.1.5.17.4.31.2.2
1.3.6.1.4.1.890.1.5.17.4.31.2.1
1.3.6.1.4.1.890.1.5.17.4.31.2.2
1.3.6.1.4.1.890.1.5.17.4.31.2.1
1.3.6.1.4.1.890.1.5.17.4.31.2.1
1.3.6.1.4.1.890.1.5.1.1.2
1.3.6.1.4.1.890.1.5.17.4.31.2.1
1.3.6.1.4.1.890.1.5.17.4.31.2.2
1.3.6.1.4.1.890.1.5.17.4.31.2.1
1.3.6.1.4.1.890.1.5.17.4.31.2.1
OBJECT ID
1.3.6.1.6.3.1.1.5.4
1.3.6.1.4.1.890.1.5.17.4.31.2.2
OLT2406 User's Guide
612
DESCRIPTION
This trap is sent when the OLT is turned on.
This trap is sent when the OLT restarts.
This trap is sent when the fan speed goes
above or below the normal operating
range.
This trap is sent when the fan speed returns
to the normal operating range.
This trap is sent when the temperature goes
above or below the normal operating
range.
This trap is sent when the temperature
returns to the normal operating range.
This trap is sent when the voltage goes
above or below the normal operating
range.
This trap is sent when the voltage returns to
the normal operating range.
This trap is sent when the OLT automatically
resets.
This trap is sent when the OLT resets by an
administrator through a management
interface.
This trap is sent when the OLT reboots by an
administrator through a management
interface.
This trap is sent when the OLT fails to get the
time and date from a time server.
This trap is sent when the OLT gets the time
and date from a time server.
This trap is sent when intrusion lock occurs on
a port.
This trap is sent when loopguard shuts down
a port.
DESCRIPTION
This trap is sent when the Ethernet
link is up.
This trap is sent when the Ethernet
link is up.

Advertisement

Table of Contents
loading