21 - 286
AUTOMATIC - NAG1 SERVICE INFORMATION
ZH
Shift Pressure Shift Valve
Each shift group possesses one shift pressure shift valve (4). The 1-2 / 4-5 and 2-3 shift pressure shift valves are
installed in the shift valve housing; the 3-4 shift pressure shift valve is installed in the valve housing. It assigns the
shift pressure (p-S) to the activating actuator and the overlap pressure (p-Ü) regulated by the overlap regulating
valve to the deactivating actuator.
Lubrication Pressure Regulating Valve
The lubrication pressure regulating valve (1) is located
in the valve housing of the electrohydraulic control
module. The valve controls the fluid to lubricate and
cool the mechanical part of the transmission, and lim-
its the pressure in the torque converter.