ZH
9860 TRUNK LATCH ACTUATOR UNLOCK CONTROL CIRCUIT SHORT TO GROUND (CONTINUED)
2.
Trunk Latch Actuator Unlock Control Circuit For Short To Ground
Turn the ignition off.
Disconnect the Power Top Control Module C1 harness connector.
Note: Check connectors — Clean/repair as necessary.
Measure the resistance between ground and the Trunk Latch Actuator
Unlock Control circuit.
Is the resistance below 100 kohms?
Yes
>> Repair the Trunk Latch Actuator Unlock Control circuit for
a short to ground.
Perform POWER TOP CONTROL MODULE VERIFICA-
TION TEST.
No
>> Replace the Power Top Control Module.(Refer to 8 -
ELECTRICAL/ELECTRONIC
POWER TOP CONTROL MODULE - REMOVAL).
Perform POWER TOP CONTROL MODULE VERIFICA-
TION TEST.
CONTROL
MODULES/
CONVERTIBLE TOP 23 - 141