Download  Print this page

Arms Error Messages - GRAPHTEC CE6000 SERIES User Manual

Graphtec ce6000 series cutting plotter.
Hide thumbs

Advertisement

ARMS Error Messages

Symptom
LCD Display
E04001
E04002
E04003
E04004
E04005
E04006
E04007
E04008
E04009
E04010
E04011
E04012
Possible Cause
Tilt to adjust with AXIS ALIGNMENT is too
large.
It is over the setting range of the distance
adjust.
Failed to adjust the sensor level.
It is over the setting range of the distance
adjust.
Could not scan the registration marks.
Amount of data has exceeded the I/O
buffer size for the segment area registration
mark.
Test pattern plotting position is not within
the plotting area for sensor position
adjustment.
Media end was detected while detecting
the registration mark.
It has exceeded detection area while
detecting the registration mark.
It has exceeded detection area while
detecting the registration mark.
It has exceeded detection area while
detecting the registration mark.
It has exceeded detection area while
detecting the registration mark.
13-9
Solution
Reload the media.
Reset to smaller value.
This media cannot be used.
Reset to smaller value.
Check the registration scan position.
Decrease the data.
Move the media toward center and plot the
test pattern.
Check the media. Check the print position
of the registration mark.
Check the media. Check the print position
of the registration mark.
Check the media. Check the print position
of the registration mark.
Check the media. Check the print position
of the registration mark.
Check the media. Check the print position
of the registration mark.

Advertisement

Table of Contents

   Also See for GRAPHTEC CE6000 SERIES

   Related Manuals for GRAPHTEC CE6000 SERIES

Comments to this Manuals

Symbols: 0
Latest comments:
  • NileshPatel Sep 06, 2019 07:37:
    I’m Ploter,Las​er,Cnc engineer. 6000 model any eligal hardware or any error guaranteed repair you bord.here Chep lavel work,
    My contact number +91 9376126262​, call any whatsapp
    Rushi Technology (india)
  • Manouchehr Niazkhani Jul 01, 2019 02:44:
    I couldent belive these issues about graphtec ce6000-60;​a lot of problems with deferent illegal code,what can I do?dont have enouph money to pay for repairing my Graphtec!
  • Ravi Nov 24, 2018 08:11:
    My graphtec ce6000-60 showing error message e01009 hardware illagele code... Plz solve my problem
  • Jishad Jan 10, 2018 08:16:
    my graphtec ce 6000-60 showing an error message
    Hardware illegal code. Can you solve this
  • sina oyekunle Dec 21, 2017 02:44:
    my graphtec ce 6000-60 showing an error message: check cam_b-pcb