Arms Error Messages - GRAPHTEC CE6000 SERIES User Manual

Graphtec ce6000 series cutting plotter
Hide thumbs Also See for CE6000 SERIES:
Table of Contents

Advertisement

ARMS Error Messages

Symptom
LCD Display
E04001
E04002
E04003
E04004
E04005
E04006
E04007
E04008
E04009
E04010
E04011
E04012
Possible Cause
Tilt to adjust with AXIS ALIGNMENT is too
large.
It is over the setting range of the distance
adjust.
Failed to adjust the sensor level.
It is over the setting range of the distance
adjust.
Could not scan the registration marks.
Amount of data has exceeded the I/O
buffer size for the segment area registration
mark.
Test pattern plotting position is not within
the plotting area for sensor position
adjustment.
Media end was detected while detecting
the registration mark.
It has exceeded detection area while
detecting the registration mark.
It has exceeded detection area while
detecting the registration mark.
It has exceeded detection area while
detecting the registration mark.
It has exceeded detection area while
detecting the registration mark.
13-9
Solution
Reload the media.
Reset to smaller value.
This media cannot be used.
Reset to smaller value.
Check the registration scan position.
Decrease the data.
Move the media toward center and plot the
test pattern.
Check the media. Check the print position
of the registration mark.
Check the media. Check the print position
of the registration mark.
Check the media. Check the print position
of the registration mark.
Check the media. Check the print position
of the registration mark.
Check the media. Check the print position
of the registration mark.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents