9
Using the scanned registration mark for adjusting, measure
the distance of how much the comparison registration mark
needs to be moved so both will overlap, and record the
value. As an example, in the figure above, it needs to move in
negative directions for both X and Y directions, so both of the
adjustment values will be a negative values.
10
Press the [3] key (X).
SENSOR OFFSET ADJ. X screen is displayed.
11
Press the POSITION (
setting value. Set the X value measured in step 9.
12
Confirm the setting and press the POSITION ( ) key
(PREVIOUS).
SENSOR OFFSET ADJ. is selected and it will return to SENSOR
OFFSET ADJ. screen.
13
Press the [4] key (Y).
SENSOR OFFSET ADJ. Y screen is displayed.
14
Press the POSITION (
setting value. Set the Y value measured in step 9.
15
Confirm the setting and press the POSITION ( ) key
(PREVIOUS).
SENSOR OFFSET is selected and it will return to SENSOR OFFSET
ADJ. screen.
) key and increase or decrease the
) key and increase or decrease the
5-32
Supplement
Position of the registration mark is measured
at the center of the line.
Supplement
Setting range is from -3.0mm to +3.0mm.
Supplement
Setting range is from -3.0mm to +3.0mm.

Advertisement

Troubleshooting

   Also See for GRAPHTEC CE6000 SERIES

Comments to this Manuals

Symbols: 0
Latest comments:
  • Jishad Jan 10, 2018 08:16:
    my graphtec ce 6000-60 showing an error message
    Hardware illegal code. Can you solve this
  • sina oyekunle Dec 21, 2017 02:44:
    my graphtec ce 6000-60 showing an error message: check cam_b-pcb
  • jitendra solanki Jun 14, 2017 05:31:
    i want ce6000 series user manual pdf file