Setting the Acceleration

Set the acceleration of the tool that is used in each of the tool condition numbers.
Setting range : CE6000-40 : 1 to 3
: CE6000-60 : 1 to 3
: CE6000-120 : 1 to 2
Supplement
On the CE6000-60, if you set speed as 64 and acceleration as 3, they will both appear as "*". In this case, both values will be
automatically calculated.
On the CE6000-120, if you set acceleration as 2, the speed cannot be set to 65 or more (65, 70, or 71). In this case, the speed and
acceleration will both appear as "*". Both values will be automatically calculated.
Operation
1
Press the [COND/TEST] key in the default screen.
CONDITION setting screen (1/3) is displayed.
2
Press the POSITION ( ) key.
CONDITION setting screen (2/3) is displayed.
3
Press the [1] key (ACCELERATION).
ACCEL setting screen is displayed.
* Display may vary depending on the selected tool condition number.
4
Press the POSITION (
number (CONDITION No.).
) key and select the tool condition
2-42
Supplement
Perform the settings in Normal mode.
Supplement
It will return to CONDITION screen (2/3)
without changing the settings when you press
the [4] key (CANCEL) .